HVLSFANS.CNHVLS Fan Engineering & Selection Center

Planning Scenario: Welding and Fabrication Plant with Heat, Dust and Long Shifts

Last updated: 2026-11-08

A welding and fabrication plant has heat sources at the welding and cutting stations, dust in the air from grinding and fabrication work, and production that runs long hours over two shifts. This is a planning scenario, not a project record: it shows how the selection answer is reached and what an engineering review still has to confirm.

What constraints do heat, dust and two-shift running set?

The selection answer

Start the review with the Paragon RTF-FF-7EEX, the 7.3 m gear-drive model with a NORD S3 drive. It is the starting point because its rated input power is 1.1 kW — lower than the 1.5 kW rating of the other two 7.3 m models — in a plant where many positions may run long hours. That is a comparison of published ratings, not a savings claim: actual energy depends on how the fans are run. The wider factory method behind this scenario is set out in the factory fan layout guide.

Item Paragon RTF-FF-7EEX
Drive NORD S3 gear drive
Blades 5
Diameter 7.3 m
Max airflow 13,800 m³/min
Input power 1.1 kW
Noise 42 dBA
Weight 115 kg

Use rated power honestly when hours are compared. Daily energy in kWh = input power in watts × operating hours ÷ 1000. On that formula, one position at the Paragon’s rated 1,100 W uses 1.1 kWh per operating hour at rated input, against 1.5 kWh for a position rated at 1,500 W. Compare all five series on the model selection page before the review closes.

This page states no fan quantity. Quantity, final positions and mounting heights are outputs of an engineering review of the plant drawings, not of a scenario.

What must still be verified

FAQ

Why does input power carry more weight in this scenario?

Because the plant runs long hours over two shifts. The energy formula uses rated input power and hours, so a lower rated input per position — 1.1 kW against 1.5 kW — is a real, documented difference when hours are long. It is still only one factor beside airflow, structure and position.

Does dust rule out a gear-drive fan?

Dust does not settle the drive choice on its own. It adds cleaning, inspection and service checks that the review confirms for the specific model and position before selection is final.

Can fans replace the plant’s extraction?

No. This scenario plans fans alongside the existing extraction and ventilation. The review checks how positions interact with that equipment; it does not treat a fan as a substitute for it.

Plan this welding plant scenario

Run your plant dimensions, clear height and shift hours through the planning calculator to organise the inputs and flag the review conditions. Then send the line layout and heat-source details through the layout request page for an engineering review.