Planning Scenario: Welding and Fabrication Plant with Heat, Dust and Long Shifts
Last updated: 2026-11-08
A welding and fabrication plant has heat sources at the welding and cutting stations, dust in the air from grinding and fabrication work, and production that runs long hours over two shifts. This is a planning scenario, not a project record: it shows how the selection answer is reached and what an engineering review still has to confirm.
What constraints do heat, dust and two-shift running set?
- Heat is local, not even — welding, cutting and other hot processes load some stations far more than others.
- Dust settles on blades, motor housings and fixings, so cleaning and inspection access is part of the layout, not an afterthought.
- Long two-shift hours mean rated input power per position adds up across the day, so it is a documented factor in the choice.
- Welding and fabrication work often runs under existing extraction and ventilation, and fan positions have to be checked against that equipment.
- Workstations and benches are fixed, so air has to arrive at set stations along the lines.
- Cranes, gantries and line-side services may limit mounting points and clear height in parts of the plant.
The selection answer
Start the review with the Paragon RTF-FF-7EEX, the 7.3 m gear-drive model with a NORD S3 drive. It is the starting point because its rated input power is 1.1 kW — lower than the 1.5 kW rating of the other two 7.3 m models — in a plant where many positions may run long hours. That is a comparison of published ratings, not a savings claim: actual energy depends on how the fans are run. The wider factory method behind this scenario is set out in the factory fan layout guide.
| Item | Paragon RTF-FF-7EEX |
|---|---|
| Drive | NORD S3 gear drive |
| Blades | 5 |
| Diameter | 7.3 m |
| Max airflow | 13,800 m³/min |
| Input power | 1.1 kW |
| Noise | 42 dBA |
| Weight | 115 kg |
Use rated power honestly when hours are compared. Daily energy in kWh = input power in watts × operating hours ÷ 1000. On that formula, one position at the Paragon’s rated 1,100 W uses 1.1 kWh per operating hour at rated input, against 1.5 kWh for a position rated at 1,500 W. Compare all five series on the model selection page before the review closes.
This page states no fan quantity. Quantity, final positions and mounting heights are outputs of an engineering review of the plant drawings, not of a scenario.
What must still be verified
- Cleaning and inspection access at each position — can blades, housing and fixings be reached safely in a dusty plant, on the inspection schedule the documentation sets?
- Clearances from heat sources at each position, checked against the selected model’s installation documentation.
- How fan positions interact with the plant’s existing extraction and ventilation equipment.
- The heat-source map: which stations generate heat, where they stand, and whether they run on both shifts.
- The structure at each mounting point, checked for the fan’s 115 kg weight and its operating loads, plus any crane or gantry envelope.
- Ceiling services and clear height in each area of the plant.
- The electrical supply at each position, checked against the model’s published rating, and the gear-drive service items in the maintenance plan.
FAQ
Why does input power carry more weight in this scenario?
Because the plant runs long hours over two shifts. The energy formula uses rated input power and hours, so a lower rated input per position — 1.1 kW against 1.5 kW — is a real, documented difference when hours are long. It is still only one factor beside airflow, structure and position.
Does dust rule out a gear-drive fan?
Dust does not settle the drive choice on its own. It adds cleaning, inspection and service checks that the review confirms for the specific model and position before selection is final.
Can fans replace the plant’s extraction?
No. This scenario plans fans alongside the existing extraction and ventilation. The review checks how positions interact with that equipment; it does not treat a fan as a substitute for it.
Plan this welding plant scenario
Run your plant dimensions, clear height and shift hours through the planning calculator to organise the inputs and flag the review conditions. Then send the line layout and heat-source details through the layout request page for an engineering review.