HVLS Fan Model Selection: The Five RTFANS Series Compared
Last updated: 2026-11-08
Model selection is where HVLS technology meets a specific building. This page puts all five current RTFANS series in one verified specification table and works through the factors — diameter, drive type, noise and weight — that decide which models belong on a shortlist. It makes no fan-quantity promises: how many fans a space needs comes from a layout review, not a table.
How do the five RTFANS series compare?
Every figure in the table below is the published rating of that specific model, and full product specifications, installation requirements and documentation for each series are published on koolairint.com.
| Series | Model | Drive | Blades | Diameter | Max airflow | Input power | Noise | Weight |
|---|---|---|---|---|---|---|---|---|
| King | RTF-CF-7EEX | NORD gear motor | 6 | 7.3 m (24 ft) | 15,500 m³/min | 1.5 kW | 43 dBA | 135 kg |
| Paragon | RTF-FF-7EEX | NORD S3 gear drive | 5 | 7.3 m | 13,800 m³/min | 1.1 kW | 42 dBA | 115 kg |
| Charm | RTF-DF-7E-1EX | PMSM direct drive | 6 | 7.3 m | 15,500 m³/min | 1.5 kW | 39 dBA | 120 kg |
| Virtue | RTF-SF-5EEX | NORD S1 gear drive | 5 | 4.7 m (16 ft) | 9,000 m³/min | 0.55 kW | 40 dBA | 55 kg |
| Grace | RTF-YF-4EEX | PMSM direct drive | 5 | 4.0 m (13 ft) | 7,500 m³/min | 0.55 kW | 38 dBA | 38 kg |
The King additionally carries a published speed range of 20–53 RPM and a 220/380 V supply rating.
How do I choose the right fan diameter?
Diameter is the first filter, because it interacts directly with ceiling height and floor layout. The range divides into full-size 7.3 m series (King, Paragon, Charm) and mid-size series at 4.7 m (Virtue) and 4.0 m (Grace). Smaller-diameter models exist for spaces where a 7.3 m fan does not fit the structure or the mounting height, and which model suits a given ceiling must be confirmed against that model’s installation manual and a structural review, not assumed from diameter alone.
How do I choose between gear drive and PMSM drive?
At 7.3 m there is a genuine drive choice: gear drive (King, Paragon) or PMSM direct drive (Charm), where PMSM means a permanent-magnet synchronous motor driving the hub with no gearbox. The gear-drive route offers a conventional NORD geared drive package with the gearbox as a scheduled service item, while the PMSM route removes the gearbox and, in this range, carries the lower published noise rating at that diameter. The PMSM vs geared comparison and the motor types guide work through the trade-offs, and neither drive is a default answer.
How much do noise and weight differ by model?
Use published figures, model by model: noise ratings run from 43 dBA (King) to 38 dBA (Grace), which matters where people spend long periods under the fan. Weight runs from 135 kg (King) down to 38 kg (Grace) and feeds directly into the structural review of the mounting point — a lighter model is not automatically the right one, but its weight may decide what a given structure can accept.
How do I compare running energy between models?
Compare running energy using each model’s rated input power and the same duty assumption: daily energy in kWh = input power in watts × operating hours ÷ 1000. On that basis a 1.5 kW model and a 0.55 kW model can be compared honestly for a stated number of operating hours, without savings percentages or payback claims — those depend on the building and its existing ventilation, and this site does not publish them.
What happens after I make a shortlist?
A shortlist is not a layout, because quantity and positions depend on dimensions, ceiling height, structure and obstructions, so the next step is a layout review. The HVLS fan calculator includes an interactive Model Selector tool that works through the planning inputs and selection factors above, and its output is a starting point for engineering review, not a final specification.
What do buyers ask most about HVLS fan model selection?
Which series is the flagship?
The King is the range’s gear-drive reference design — the model the other series are most often compared against. That makes it a common starting point for industrial shortlists, not a universal recommendation.
King or Charm at 7.3 m?
Both are rated at 15,500 m³/min: the King is gear-drive at 43 dBA and 135 kg, and the Charm is PMSM direct drive at 39 dBA and 120 kg. The choice turns on drive and service preference, noise sensitivity and structure.
Can this page tell me how many fans my warehouse needs?
No — and it is designed not to. Quantity comes from layout, spacing and obstructions in your specific building, so use the Model Selector on the calculator page for a first pass, then have the layout reviewed.
Request a Model Recommendation
Send your building type, dimensions and ceiling height through the layout request page, and say which factor drives the decision — diameter, noise, drive or structure. The team will review the shortlist against the building; the technology center explains the motor, blade and control background.
Compare the Verified RTFANS Range
All figures are the published, verified specifications for each flagship model. Filter by drive type or minimum diameter, and tick models to compare side by side.
| Series | Model | Drive | Blades | Diameter | Airflow | Power | Noise | Weight | Typical fit | Compare |
|---|---|---|---|---|---|---|---|---|---|---|
| King | RTF-CF-7EEX | NORD gear motor | 6 | 7.3 m / 24 ft | 15,500 m³/min | 1.5 kW | 43 dBA | 135 kg | Heavy-duty industrial reference design | |
| Paragon | RTF-FF-7EEX | NORD S3 gear drive | 5 | 7.3 m / 24 ft | 13,800 m³/min | 1.1 kW | 42 dBA | 115 kg | Five-blade design series for large spaces | |
| Charm | RTF-DF-7E-1EX | PMSM direct drive | 6 | 7.3 m / 24 ft | 15,500 m³/min | 1.5 kW | 39 dBA | 120 kg | Quiet direct-drive for commercial interiors | |
| Virtue | RTF-SF-5EEX | NORD S1 gear drive | 5 | 4.7 m / 16 ft | 9,000 m³/min | 0.55 kW | 40 dBA | 55 kg | Mid-size industrial spaces | |
| Grace | RTF-YF-4EEX | PMSM direct drive | 5 | 4 m / 13 ft | 7,500 m³/min | 0.55 kW | 38 dBA | 38 kg | Latest-generation compact direct drive |